AX500 Motor Controller User’s Manual 117
Accessing & Changing Configuration Parameter in Flash
Input Switches Function
Address: ^04
Access: Read/Write
Effective: After Reset or ^FF
This parameter enables and configures the effect of the controller’s Digital Inputs and other
settings.
Bit Definition See pages
7:0 0 = very slow
1 = slow
(2) = medium-slow (default)
3 = medium
4 = fast
5 = fastest
See “Programmable Acceleration”
on page 41 for complete list of
acceptable values
Bit Definition See pages
1:0 Enable and
Configure
Invert/Estop
(00) = Input Disabled (default)
01 = Input as Emergency Stop
10 = Disabled
11 = Input as Invert Command
page 45
page 45
2 Output C when
Motor On
(0) = No Action (default)
1 = Output C On when either motor is On
page 45
3 Encoder Safety Unavailable
5:4 Input E Unavailable when Encoder Module is
present
(00) = No action (default)
01 = Cut FET power when Input E is Low
10 = Activate output C
11 = Cut FET when Input E is High
page 46
page 46
7:6 Input F (00) = No action (default)
01 = Cut FET power when Input E is Low
10 = Activate output C
11 = Cut FET when Input E is High
page 46
page 46